[Celestica] Leh800bcls: Fix AgentTrunkTest crash in multi-NPU environment by passing platform type in config generation - #1501
Open
gang-tao wants to merge 1 commit into
Open
Conversation
…ment by passing platform type in config generation
Contributor
|
@jchallag has imported this pull request. If you are a Meta employee, you can view this in D115625858. |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Pre-submission checklist
pip install -r requirements-dev.txt && pre-commit installpre-commit runSummary
Fixes a crash in fboss_hw_agent during AgentTrunkTest cases in multi-NPU (Split Agent) environments. fboss_hw_agent0 crashed with 'counter_get() failed(Invalid unit)' during initialization.
Root Cause
In
AgentTrunkTest::initialConfig(), the configuration was generated by callingutility::oneL3IntfTwoPortConfig()without passing theplatformType. In multi-NPU environments, omitting the platform type causes the configuration generator to fall back to a single-NPU configuration.Solution
In
utility::oneL3IntfTwoPortConfig()to explicitly pass theplatformType(retrieved viaensemble.getSw()->getPlatformType()).Test Plan
Successfully ran and verified all Trunk tests on Leh800bcls platform (NPU0 and NPU1):